Dual Channel Real Time Quantitative PCR Detection System (DW-TL988-II)

Model NO.: DW-TL988-II
Power Supply: 220V
Weight: 0-50kg
Certification: CE
Customized: Non-Customized
Block Formats: 48well
Sample Volume: 10-100 UL
Max Heating/Cooling Rate: 3.0c/Sec/ 2.0 C/Sec
Temperature Range: 4.0-99.0 C
Temperature Accuracy: +-0.1 C
Temperature Uniformity: +-0.3 C
Temperature Steps: 1-99
Heated Lid: 100-120 C
Operating Systems: Windows XP,Windows 7
Trademark: Drawell
Transport Package: Carton Packing
Specification: 520Wx420Dx320H mm
Origin: Shanghai
HS Code: 8419899090
Model NO.: DW-TL988-II
Power Supply: 220V
Weight: 0-50kg
Certification: CE
Customized: Non-Customized
Block Formats: 48well
Sample Volume: 10-100 UL
Max Heating/Cooling Rate: 3.0c/Sec/ 2.0 C/Sec
Temperature Range: 4.0-99.0 C
Temperature Accuracy: +-0.1 C
Temperature Uniformity: +-0.3 C
Temperature Steps: 1-99
Heated Lid: 100-120 C
Operating Systems: Windows XP,Windows 7
Trademark: Drawell
Transport Package: Carton Packing
Specification: 520Wx420Dx320H mm
Origin: Shanghai
HS Code: 8419899090
Real-time Quantitative PCR Detection System DW-TL988-II
 

Key Feature
1.48 samples
2.Easy-to-use Software
3.Various Operation modes
4.Advantange Temperature Control
5.Non-Maintenance Optical Systems
6.Sensitive and Precise Thermoelectric Systems
7.Particular Momentary Power Failure Protection
 
Specifications
Thermal Block                                             
Block formats           48-well
Sample volume          10-100 μL
Consumables   Thick-walled 0.2ml PCR tibes, 0.1ml 8-strip tubes
Max heating/cooling rate          3.0°C/sec/ 2.0°C/sec
Temperature range        4.0-99.0°C
Temperature accuracy      ±0.1ºC
Temperature uniformity      ±0.3°C
Temperature steps          1-99
Heated lid                                                   
Temperature range    100-120°C
Optics                                                     
Excitation          2 LEDs
Excitation range     470-523 nm
Detector           PMT
Detection range     525-564nm
Detection channels:
Channel          Excitation (nm)     Emission (nm)      Pre-Calibrated Dyes
1.                 470               525             FAM, SYBR Green I
2.                 523               564             VIC, HEX, TET, JOE
Detection range       101-1010 copies
Software                                                     
Analysis modes:   Relative quantification,
                Melt curve analysis,
Performance                                                
Reproducibility                                   CV≤2.1%
Correlation coefficient of nucleic acid precision         R≥0.997
System                                                    
Operating systems       Windows XP,Windows 7
Communication         USB
Power usage           AC220 × (1±10%)V, 50 × (1±2%)Hz
Dimensions            520W×420D×320H mm
Weight               27kg
 
Dual Channel Real Time Quantitative PCR Detection System (DW-TL988-II)

Dual Channel Real Time Quantitative PCR Detection System (DW-TL988-II)
Dual Channel Real Time Quantitative PCR Detection System (DW-TL988-II)
Dual Channel Real Time Quantitative PCR Detection System (DW-TL988-II)
Dual Channel Real Time Quantitative PCR Detection System (DW-TL988-II)
Dual Channel Real Time Quantitative PCR Detection System (DW-TL988-II)




  Real-time Quantitative PCR Detection System DW-TL988-II
 

Key Feature
1.48 samples
2.Easy-to-use Software
3.Various Operation modes
4.Advantange Temperature Control
5.Non-Maintenance Optical Systems
6.Sensitive and Precise Thermoelectric Systems
7.Particular Momentary Power Failure Protection
 
Specifications
Thermal Block                                             
Block formats           48-well
Sample volume          10-100 μL
Consumables   Thick-walled 0.2ml PCR tibes, 0.1ml 8-strip tubes
Max heating/cooling rate          3.0°C/sec/ 2.0°C/sec
Temperature range        4.0-99.0°C
Temperature accuracy      ±0.1ºC
Temperature uniformity      ±0.3°C
Temperature steps          1-99
Heated lid                                                   
Temperature range    100-120°C
Optics                                                     
Excitation          2 LEDs
Excitation range     470-523 nm
Detector           PMT
Detection range     525-564nm
Detection channels:
Channel          Excitation (nm)     Emission (nm)      Pre-Calibrated Dyes
1.                 470               525             FAM, SYBR Green I
2.                 523               564             VIC, HEX, TET, JOE
Detection range       101-1010 copies
Software                                                     
Analysis modes:   Relative quantification,
                Melt curve analysis,
Performance                                                
Reproducibility                                   CV≤2.1%
Correlation coefficient of nucleic acid precision         R≥0.997
System                                                    
Operating systems       Windows XP,Windows 7
Communication         USB
Power usage           AC220 × (1±10%)V, 50 × (1±2%)Hz
Dimensions            520W×420D×320H mm
Weight               27kg
 
Dual Channel Real Time Quantitative PCR Detection System (DW-TL988-II)

Dual Channel Real Time Quantitative PCR Detection System (DW-TL988-II)
Dual Channel Real Time Quantitative PCR Detection System (DW-TL988-II)
Dual Channel Real Time Quantitative PCR Detection System (DW-TL988-II)
Dual Channel Real Time Quantitative PCR Detection System (DW-TL988-II)
Dual Channel Real Time Quantitative PCR Detection System (DW-TL988-II)




 

LED Flood Light

LED floodlight is a kind of can be all directions even illuminate the point light source, it can adjust the illuminate of scope, performance in the scene for a graphic is octahedron.
Product features,
floodlight uniformly in all directions from a particular point ground illuminate objects, use it to light bulbs and candle analogy is best. floodlight can be placed anywhere in the scene.For example, can be placed outside the scope of camera, or is the inside of the object. In the cosco distance of the scene using many different colored floodlight is very common.These floodlights can mix and dark projection on the model.Because the illuminate of floodlight range is big, so the floodlight light effect is very easy to predict, and the lights and many auxiliary USES, for example, place the floodlight near the surface of the object position, will create a bright light on the surface.

Led Flood Light,Aluminum Die Casting Flood Light,High Intensity Led Flood Lights,Outdoor Led Flood Lighting

NINGBO ZHENHAI BOLANG METAL PRODUCT FACTORY , https://www.aldiecastings.com