Rated voltage
3V DC
Working stroke
0.3±0.2mm
Spring load
≥75g(when closing valve)
Operation voltage
<1.6V(pressure 5kPa)
Maintaining voltage
<2.2V
Release voltage
>0.1V
Operating coil resistance
7Ω+10%-5%
Maintaining coil resistance
600Ω+10%-5%
Insulation resistance
>5MΩ
External leakage
<0.03L/h
Internal leakage
<0.07L/h
Life test
30,0000 times