High-temperature aging room laboratory safety knowledge training
Ch/Cs Cone Crusher Parts,Mining Parts,Damper Parts,Eccentric Wearing Plate Shenyang Ule Mining Machinery Co., Ltd , https://www.ulecrusherparts.com
When users use high-temperature aging room lab, what security risks need to be prevented? What are the precautions when operating an aging room? Which products are prohibited in high temperature aging room test? The following is a high-temperature aging room laboratory design expert - Corwin discusses with you the safety knowledge of the aging laboratory.
1 Electronically controlled design Refer to "Low Voltage Distribution Design Specification" GB50054-95, "Design Specification for Power Supply and Distribution" GB5002S2-95, "Code for Construction and Acceptance of Grounding Devices of Electrical Installation Engineering" GB50169-92, standardize electrical control design.
2 control system integration aging function design. Design function control cabinet, time required for aging, temperature, all kinds of operation switch can be operated on a control panel; the panel design of the panel is beautiful and easy to operate.
3 The aging process can be fully automatic control, with some abnormal self-processing functions, allowing the operation to be automated and simplified.
4 with multiple protection features, safe and reliable.
a. Electric anti-dry burning, when the fan fails or the temperature in the air duct is too high, the power of the circulating system will be automatically cut off, and the alarm will alarm.
b. The linkage design of electric heating and fan, when the fan fails to start, the heater can not be started separately. At the time of closing, the electric heat and the circulation fan are closed at the same time to prevent the electric heating from damage due to dry burning.
c. Heater connection adopts high temperature resistant wire, 300OC does not burn.
d. Indoor installation of explosion-proof lighting, increase lamp life and prevent bulb explosion.
e. The use of flame-retardant insulation materials in the library, good insulation performance and high safety factor.
f. Smoke alarm function: Smoke alarm is installed in the room to prevent the product from burning and alarm in the process of aging products, and automatically shut down the power of the aging room when the alarm occurs.
g. Over-temperature sound and light alarm function: In the over-temperature condition during the aging process, the red light is on and the buzzer sounds.
The main safety protection measures for high-temperature aging rooms are as described above. If you need any help from Kevin, please feel free to contact us. No matter what brand you use, what age of high-temperature aging rooms, Kevin technical experts can provide you with the most comprehensive service support!